Our testing process

Every published ARQIVANE certificate comes from Axiom Analytics Laboratories, an outside testing lab. This is the path each batch takes, from a sealed vial to a record you can check.

  1. A sealed vial goes to the lab

    A sealed vial from the batch is sent to the lab. The certificate records how it arrived: batch number, label claim, cap and seal condition, and photos of the vial as received.

  2. Five tests on every certificate

    TestWhat it checksMethod on the certificate
    IdentityThat the material is the right moleculeMass spectrometry (LC-MS): observed mass against theoretical mass
    PurityHow much of the peptide material is the target compoundReverse-phase HPLC, reported as area %
    Net contentHow much target compound is in the vial, against the labelQuantitative HPLC against a reference standard
    Sterility screenWhether microbial DNA is presentRapid PCR research screen (not a USP <71> sterility test)
    Fentanyl screenWhether fentanyl or listed analogs are present above the detection limitTargeted LC-MS/MS screen
  3. The record is sealed at the lab

    Each certificate carries a report ID and a QR code. The lab keeps a sealed record of the results, so you can check a certificate on the lab’s own site instead of trusting a PDF.

  4. You match it to your vial

    Certificates are published by product and batch. Match the batch number on your vial’s label to its certificate. A product without a published certificate shows “Certificate coming soon” in the store.

A certificate describes the sample that was tested. The certificate itself states that results relate only to the item tested, so always match the batch number on your vial to the batch on the certificate.